+ 200 KVA
+ UL60601-1
+ Small Footprint Design for Medical Application
+ Digital Signal Processing Technology
+ Instant Protection against Power Spikes, Swells, Sag
+ Superior Sub Cycle Voltage Stabilization of 1%
+ Independent Phase Control
+ Seamless Redundant Power Paths
+ Service without Shutdown
+ Advanced Remote Monitor
+ *Expandable Battery Back up
+ 12 pulse Harmonic Reduction
+ Intelligent charger with temperature compensation
+ Intelligent Safe Battery Test Circuitry
+ Intelligent Fan Speed Control
+ Low Heat Dissipation
+ Front Service Clearance Only
+ *Battery Monitoring System
+ **Upgradeable to UPS
+ Fully Modular for Quick Service
+ Light Weight, Easy Installation, Plug and Play
+ LCD panel with 24 LED status and alarm indicators
+ Support Complex Power Factor Loads
+ User Friendly Proven Technology
INPUT | |
Input Voltage | 208 or 480 VAC |
Output Voltage | 208Y/120 or 480Y/277 VAC |
Frequency | 50 or 60 Hz, ±5% |
OUTPUT | |
Power Rating | 10, 15, 20, 25, 30, 40, 50, 60, 80, 100, 120, 160, 200 kVA (consult factory for other sizes) |
Power Factor Rating | 0.8 |
Voltage | 480 VAC, 3 Phase, 4 Wires + Gnd |
Crest Fator | 3:1 |
Voltage Regulation | ±1% |
Dynamic Regulation | ±2% for Step Load |
Phase Imbalance | V thd <2% |
Frequency Stability | ±1% |
Overload Rating | 150% for 30 Seconds, 125% for 15 minutes |
Neutral | Newly derived and bonded to earth |
PHYSICAL |
|
Cabinet Dimensions | 44"W x 31.5”D x 63”H (w/Batteries) |
Electrical Connection | Front Access |
Cable Entry/Exit | Bottom |
Service Clearance | Modular design for ease of service (Front Only) |
Operating Temperature | 32°(0°C) to 10c°F (40°C) (control cabinet), 25˚C (77˚F) (battery cabinet) |
Operating Humidity | 10 to 90% non-condensing |
Seismic Anchoring | Mounting Brackets (optional) |
SYSTEM | |
Configuration | Three Phase UPS modular design for easy of service |
Topology | Advanced Double Conversion |
Technology | Redundant DSP, microprocessor |
Efficiency | 92% typical |
Bypass 1 | Static Reverse |
Bypass 2 | Internal Maintenance |
Audible Noise | <67 dBA at 1 Meter |
Cooling | Intelligent speed controlled Forced Air |
Heat Dissipation | 6600 BTU Typical |
COMMUNICATION | |
Interface | RS-485, RS-232, Relay Contacts |
Display | Front Mimic Panel LCD (4 lines X 40 Character backlit LCD) |
Audible Alarm | Yes / Programmable |
Emergency Shut Down | Local & remote Capability (optional) |
Network Capable | Yes (optional) |
GMS | optional |
Operating Temperature | 32°F (0°C) to 104°F (40°C) |
Storage Temperature | -4°F (-20°C) to 140°F (60°C) |
Operating Humidity | 5 to 95% non-condensing |
Cabinet Dimensions | 44"W x 31.5”D x 63”H (w/Batteries) |
Electrical Connection | Front Access |
Cable Entry/Exit | Bottom |
Service Clearance | Modular design for ease of service (Front Only) |
Seismic Anchoring | Mounting Brackets (optional) |
For Medical Equipments